Testladen

Technical specifications

All figures apply to the base chassis unless noted. Per-module electrical limits are listed in the Module overview. Values are typical at 25 °C; specifications are subject to change with firmware and hardware revisions.

Electrical

ParameterValue
Input voltage100–240 V AC, auto-ranging
Input frequency50/60 Hz
Mains inletIEC 60320 C14
Internal fuseT4 A / 250 V
Max power consumption200 W (fully populated)
Typical power (idle)35 W
Protective earthVia mains inlet; chassis bonded
Backplane rails+12 V, +5 V, +3.3 V (module-shared)

Mains inlet (IEC C14) pinout

PinSignal
LLine (live)
NNeutral
Protective earth

Mechanical

ParameterValue
Form factor19″ rack, 3U
Height132.9 mm (3U)
Width483 mm (with ears); 449 mm body
Depth600 mm (excl. connectors)
Weight (unpopulated)6.8 kg
Weight (fully populated)up to 9.5 kg
MountingFront rack ears + rail/shelf support

Interfaces

InterfaceSpecification
Management network1× 1000BASE-T, RJ45
Extension bus10BASE-T1S single-pair Ethernet (per network module)
DUT serial interfaceTODO
Console/config1× USB-C (115200 8N1)

Environmental

ParameterOperatingStorage
Temperature0 °C to +40 °C−20 °C to +70 °C
Relative humidity10–90 %, non-condensing5–95 %, non-condensing
Altitudeup to 2000 mup to 12 000 m
Ingress protectionIP20 (indoor use)
CoolingFront-to-rear forced air
Acoustic noise< 45 dB(A) at 1 m (idle)

Connector-level pinout diagrams are in the Appendix.